Club Prime Doors are Boiling Water Proof (BWP) doors of the highest quality that act as excellent insulators against dust, heat and noise. Made from the finest quality timber for high resistance and quality, these flush doors are extremely durable and come with our patented Glue Line Internal Protection that make them 100% borer and termite proof.
Years of Warranty10 Years
Bend Proof
Slam Proof
Strength
Available in:
25 mm
30 mm
32 mm
35 mm
38 mm
40 mm
Our USPs
Borer & Termite Proof
Boiling Water Proof
Slam Proof
Swell Proof
Bend Proof
Tests
IS 2202 (Part 1) Requirements
Observation
Wrokmanship and Finish
Satisfactory
Satisfactory
Dimensions and Squareness Test
Length and Width within a limit 5 mm (+/-)
Length = +/- 4 mm
Width = +/- 4 mm
Thickness within limit of 1 mm (+/-)
Thickness = +/- 0.8 mm
Door Shutter shall not deviate by more than 1 mm
Within limit
General Flatness Test
Twist, Cupping, Warping not more than 6 mm
Within Limit
Local Planeness Test
Depth of deviation not greater than 0.5 mm
Within Limit
Impact indentation Test
Not more than 0.2 mm
0.2 mm
Flexure Test
Residual Deflection should not be more than 1/10th of Maximum deflection
Within Limit
Deflection at max load should not be more than 1/30 of length and 1/15 of width
Within Limit
Edge Loading Test
Deflection of the edge at the maximum load should not be more than 5.0 mm
4.50 mm
Residual deflection should not be more than 0.5 mm
Within Limit
Lateral buckling should not be more than 2 mm during loading
1.50 mm
Shock Resistance
No delamination should be observed due to light and heavy body impact
No Delamination
Buckling Test
Residual deformation should not be more than 5.0 mm
4.00 mm
Initial deflection should not be more than 50.0 mm